Radiographic inspection is a volumetric-type test suitable for the evaluation of internal discontinuities in metallic and nonmetallic materials. It is widely used in industry to ensure the integrity and fitness for use of manufactured parts.
Traditional rx-ray
Digital Radiography
CR Technique
Computed Radiography (CR) is an imaging technique used for diagnostic and inspection purposes that replaces traditional radiographic film with flexible photostimulable phosphor (PSP) imaging plates.
How it works:
Exposure: The imaging plate (placed inside a dedicated cassette or protective sleeve) is exposed to X-rays or gamma radiation sources, creating a latent image stored in the phosphor crystals.
Reading and Digitization: The imaging plate is removed and inserted into a dedicated scanner, where a laser beam stimulates the phosphor to release stored energy in the form of light, which is then converted into a digital signal.
Erasure and Reuse: After scanning, the imaging plate is exposed to intense light to erase any residual image data, making it ready for reuse.
Reading and Digitization: The imaging plate is removed and inserted into a dedicated scanner, where a laser beam stimulates the phosphor to release stored energy in the form of light, which is then converted into a digital signal.
Erasure and Reuse: After scanning, the imaging plate is exposed to intense light to erase any residual image data, making it ready for reuse.
DR Technique
Direct Radiography (DR) is a digital imaging technique that converts X-rays directly into a digital signal within seconds, without intermediate processing steps or chemical development.
How it works:
Flat Panel Detectors: Sensors are positioned behind the object and capture the X-ray beam.
Direct or Indirect Conversion:
• Direct: Uses materials such as amorphous selenium to convert X-rays directly into electrical charges.
• Indirect: Uses a scintillator layer (such as cesium iodide) that first converts X-rays into light and then into an electrical signal.
The image appears on the computer monitor in near real-time (within 5–30 seconds after exposure).
Direct or Indirect Conversion:
• Direct: Uses materials such as amorphous selenium to convert X-rays directly into electrical charges.
• Indirect: Uses a scintillator layer (such as cesium iodide) that first converts X-rays into light and then into an electrical signal.
The image appears on the computer monitor in near real-time (within 5–30 seconds after exposure).